The woman who saw tea freeze
In 1978 a woman suffered damage to both sides of her brain. Afterward, something strange had happened to her vision. Colors looked the same as before, and things that stood still, including faces, looked perfectly clear. But when she poured tea, the stream looked frozen, like a glacier, and she couldn't pour properly. People, dogs and cars were suddenly here, then suddenly there, with nothing in between. Crossing a road became extremely difficult. She had lost the ability to see motion, and only motion. The researchers who studied her reported this in 1983.
So motion seems to be something the brain constructs separately from color and shape. What clues in the light reaching your eyes does that motion machinery actually use?
Think of a red apple and a green leaf. They look completely different, yet in a black-and-white photo they can turn into almost the same gray, because their brightness, or luminance, is nearly equal. Colors that differ in hue but have the same luminance are called isoluminant.
What happens when an isoluminant stripe pattern moves? The colors are obviously different, so you might expect the motion to be obvious too. In fact, isoluminant stripes look sluggish: they can seem slower than they really are, and sometimes they even seem to stop. Here we move a luminance grating and color stripes in opposite directions and ask which motion your eyes believe, and you will measure where your own isoluminance point lies.
Sums and differences of cone signals
Your retina has three kinds of cone cells, often called L, M and S cones. Roughly speaking, the information traveling from the eye to the brain is split into a "sum" of cone signals, which carries brightness, and "differences", which carry color contrasts such as red versus green and yellow versus blue.
The machinery that sees motion is thought to rely mainly on the "sum", that is, on changes in brightness. Move a pattern with no brightness differences at all, and for that machinery almost nothing is moving, so the motion looks weak. Measurements published in 1984 showed exactly this: slowly drifting red–green isoluminant gratings looked much slower than they were, and sometimes stopped, even though every single stripe was easy to see.
It is not quite that simple, though. Later studies showed that isoluminant patterns can still be seen to move under some conditions, and that color does make some contribution to motion perception. "Color plays no part in motion" goes too far, and how much color contributes, and through which pathways, is still being studied.
Shape and motion lean on brightness
One of the first people to notice what happens at isoluminance was the psychologist Susanne Liebmann. In a paper published in 1927 she reported that as the brightness of a colored figure approaches that of its colored background, its outline blurs and its shape simplifies. The phenomenon became known as the Liebmann effect. In 1938 a study in The Japanese Journal of Psychology found that well-formed figures such as circles and squares resist the effect best. Color difference without brightness difference turns out to have very little power to hold a shape together.
In art, colors of equal brightness placed side by side are said to shimmer at their borders or make shapes look unstable. That is the Liebmann effect again, and at least one vision scientist has discussed Impressionist paintings from this angle. Some effects painters found by experience may come from our motion and shape systems leaning on brightness.
What about motion? In the early 1970s, researchers found a region in the monkey brain packed with cells that respond to particular directions of motion, later called MT or V5.
Then in 1978 V. S. Ramachandran and Richard Gregory reported that apparent motion, the impression that successive still frames move, is hard to see in stimuli defined only by color, and asked in their title whether color provides any input to human motion perception at all. The report on the woman in the introduction appeared in 1983. Her damage lay around the border of the temporal and occipital lobes, and MT/V5 there is considered the most likely candidate for a "motion center", though whether it is the whole story is still debated.
In 1987–1988 Margaret Livingstone and David Hubel sketched a bold map in which form, color, motion and depth travel along separate pathways in the brain, with the pathway carrying motion, the magnocellular system, being color-blind. Isoluminant stimuli became a favorite tool for probing that division of labor. Later measurements showed that many magnocellular cells still respond a little at isoluminance, and Cavanagh and Anstis reported in 1991 that color does contribute somewhat to motion. There is a division of labor, but it is not clean. That is the current view.
Other animals have similar divisions. In flies, motion vision was long thought to come only from photoreceptors that can't tell colors apart, but recent studies report that color receptors contribute a little too. Sound familiar?
From screen values to luminance
First, let's compute brightness. Screen colors are given as R, G, B values from 0 to 255, but these numbers are not proportional to the amount of light. Why not? Our eyes notice small differences between dark shades but not the same differences between bright ones. Spread 256 numbers evenly over light intensity and the dark end gets too few of them. So the sRGB standard squeezes the light intensity , which runs from 0 to 1, by roughly a 1/2.4 power before turning it into a number, except for a short straight segment near black that keeps the slope from becoming infinite:
Solve for and you get the formula that turns a screen value back into light:
For very small , it is instead. For example, , which is about 128, gives in light intensity. Half the number is not half the light. Think of the 0–255 scale as the markings on a ruler with uneven spacing: the markings are crowded at the dark end, because our eyes are most sensitive to differences between dark shades and deserve more numbers there. From the linear the luminance is
assuming sRGB primaries and a standard observer. The weights are the luminances of the red, green and blue primaries, each lit alone at full strength, when the screen's white is given a luminance of 1; they add up to exactly 1. Green gets a big weight and blue a tiny one, because the eye is most sensitive to light around green.
An honest warning: equal luminance does not guarantee equal apparent brightness. Vivid reds and blues look brighter than a gray of the same luminance, which is known as the Helmholtz–Kohlrausch effect. Luminance is used anyway because it adds up. Measure it by flicker photometry, alternating two colored lights rapidly and adjusting until the flicker is smallest, and the luminance of a mixture equals the sum of the luminances of its parts. That additivity is what justifies the "weight and add" form of the formula above.
Comparing the brightness of two different colors is surprisingly hard. Put a red light next to a green one and ask which is brighter, and the answers scatter and don't add up. The fix was flicker photometry: alternate the two lights rapidly and find where the flicker is weakest. Measurements like these led the International Commission on Illumination, the CIE, to adopt a standard luminous efficiency function in 1924, with sensitivity peaking in the green, around 555 nm. Measuring isoluminance is a hundred-year-old problem.
The "lumens" printed on a light-bulb box come straight out of this story. Lumens measure light energy weighted by the sensitivity of the human eye, that is, by the standard luminous efficiency function. In the International System of Units, 1 watt of light at a frequency of 540 trillion hertz, a green of wavelength about 555 nm, is defined as 683 lumens. At the same power, light closer to the green the eye prefers gives more lumens. Every lighting label rests on flicker-photometry experiments done a century ago.
Web design uses the same luminance formula. The accessibility guidelines for text and background, known as WCAG, convert sRGB values to linear light, compute the luminance as above, call the lighter one and the darker one , and require the contrast ratio to be at least 4.5 for ordinary text. However different the hues, equal luminance gives a ratio of 1, which is very hard to read. In Japan about 5% of men and about 0.2% of women are said to have color vision that makes red and green hard to tell apart, so designs that add a brightness difference instead of relying on color alone matter.
Changing color, not luminance
How can we change the color without changing the luminance? A change changes the luminance by , so we choose directions that make this zero: yellow–blue with , and red–green . Remove one unit of blue, and adding only 0.078 to red and to green balances it, because blue's weight is so small.
Television and video signals use the "luma" , built from the gamma-encoded values . Keeping it constant sounds like keeping brightness constant. But a weighted sum of encoded values is not a weighted sum of light, so equal does not mean equal luminance . The color-construction menu in the panel lets you see the difference as a number.
Television and video, too, send the brightness signal Y′ and the color-difference signals Cb and Cr separately, a habit that began with compatibility with black-and-white sets. Because our eyes barely notice fine color detail, the color signals can be thinned out.
All of this shows that light intensity, perceived brightness and screen values are three different things. Additive color mixing, gamma correction and the YCbCr split into a brightness signal and color-difference signals all rest on that distinction. Try the luminance and color-difference mode of the "Image and Frequency Lab" simulation to see it on real images.
Hunting isoluminance with minimum motion
The moving grating is
with contrast , period and speed . The combination says "the pattern at time is the pattern at time 0 shifted right by ". How many times per second does the brightness at one point go up and down? This rate is the temporal frequency. Hold fixed: in a time the argument of the sine changes by . That reaches , one full cycle, when , so .
The minimum-motion technique is a clever way to find isoluminance. It shows a color grating, then a luminance grating, then the color grating reversed, then the luminance grating reversed, each shifted by a quarter of a period. If the yellow side of the color grating is slightly brighter, the bright parts hop a quarter period at a time in one direction. If yellow is slightly darker, they hop the other way.
To see why, think about a motion detector that looks only at luminance. The simplest way to detect motion is to multiply the signal at one place a moment ago by the signal at a neighboring place now: if the same pattern has shifted over, the product is large. This is a correlation-type detector.
In 1956 Bernhard Hassenstein and Werner Reichardt studied how a beetle turns to follow a rotating pattern and built a model of motion detection in which the signals of two neighboring facets of the eye are multiplied with a time delay. The correlation detector we are using descends from that idea.
The luminance left over in a color frame is , and in the next frame the luminance grating is , with . Multiply by the next frame a quarter period to the right, where , and average:
A quarter period to the left, where , the next frame is , so the average is . Take rightward minus leftward as the motion signal:
The motion signal is proportional to , flips direction when changes sign, and is exactly zero at . So we ask "which way did it move?" and nudge the balance up or down until the answer becomes a coin toss. The staircase in this simulation does exactly that.
In 1983, the same year as the report on the woman who saw tea freeze, Stuart Anstis and Patrick Cavanagh published the minimum-motion technique, and in 1984 Cavanagh and colleagues measured how isoluminant gratings appear to slow down.
Isoluminance is personal
There is one more twist. Isoluminance is personal. The proportions of cone types and the pigments inside the eye differ from person to person, so a red and a green that are isoluminant for one person may look slightly unequal to another. A careful experiment therefore measures each observer's isoluminance point.
The "sums and differences" used here are exactly how the retina and brain combine the signals of the three cone types. Color vision is diverse, and cones work slightly differently from person to person, so isoluminance points differ too. When your minimum-motion result differs from your neighbor's, that is not a failed measurement; it is partly this diversity showing.
Measure your own isoluminance point
- The page opens in the "Overlay (opposite directions)" display, with the stripes stopped and shown faint so that you can read the light-stimulus warning before anything moves. After reading it, press ▶ Play and the stripes start to move. Keep your eyes on the central dot. In the top band the luminance grating moves right and the color stripes move left. Which way does the whole pattern seem to move? The bottom band is the mirror image.
- Under "Display", choose "Separate (luminance / color)" to show the two components apart: luminance only at the top, color only at the bottom, at the same speed. Do the color stripes look slower? What happens when you lower "Luminance grating contrast"?
- Move "Luminance balance of color stripes " slowly and find the value at which the color stripes' motion looks weakest. Was it zero?
- Press "Measure my isoluminance point" to start the minimum-motion measurement. If the stripes seem to move right, press "Moves right →"; if left, "← Moves left". You can also use the arrow keys. δ changes after every answer, and the run ends after eight reversals. Measure a few times and look at the mean and spread.
- Under "Color construction", choose "Constant Y′ (TV luma)", and read "With constant ()" under "Results". Equal Y′ still leaves a luminance difference.
- Set "Yellow–blue strength (Y/B)" to zero, raise "Red–green strength (R/G)" and measure again. Is the isoluminance point the same?
From frozen tea to lumens
Luminance is a weighted sum of linear light intensities; adding up the 0–255 screen values directly does not give the true luminance. The motion system relies mainly on luminance differences, so isoluminant color stripes look weak and slow, although color is not completely ignored. The true isoluminance point differs between people and between screens, and the minimum-motion technique lets you measure your own.
A woman who saw tea frozen in mid-pour, Liebmann's figures melting into their backgrounds, a motion model born from a beetle's eye: these scattered stories point to one discovery. The brain handles brightness, color, shape and motion partly separately, and that division shows up even in the lumens on a bulb box and the rules for readable text.
If the motion system could use color just as well as brightness, what would an animal gain, and what might it lose?
Sources and further reading
Main sources for the facts mentioned above.
- J. Zihl & C. A. Heywood, The contribution of LM to the neuroscience of movement vision, Frontiers in Integrative Neuroscience, 2015 (the patient LM)
- J. Zihl, D. von Cramon & N. Mai, Selective disturbance of movement vision after bilateral brain damage, Brain, 1983
- V. S. Ramachandran & R. L. Gregory, Does colour provide an input to human motion perception?, Nature, 1978
- P. Cavanagh, C. W. Tyler & O. E. Favreau, Perceived velocity of moving chromatic gratings, JOSA A, 1984
- M. Livingstone & D. Hubel, Segregation of form, color, movement, and depth: anatomy, physiology, and perception, Science, 1988
- P. Cavanagh & S. Anstis, The contribution of color to motion in normal and color-deficient observers, Vision Research, 1991
- B. Yagi, The influence of form upon the Liebmann effect, Japanese Journal of Psychology, 1938 (J-STAGE, in Japanese)
- B. Hassenstein & W. Reichardt, Systemtheoretische Analyse der Zeit-, Reihenfolgen- und Vorzeichenauswertung bei der Bewegungsperzeption des Rüsselkäfers Chlorophanus, Zeitschrift für Naturforschung B, 1956
- Guan et al., Perceptual and neural constraints on photometric measures of heterochromatic brightness, 2026 (Helmholtz–Kohlrausch effect; Bournemouth University repository)
- BIPM, SI base unit: candela (683 lm/W at 540 THz)
- W3C, Understanding WCAG: relative luminance
- W3C, Understanding Success Criterion 1.4.3: Contrast (Minimum) (the 4.5:1 ratio)
Further reading (encyclopedia):